Sign In | Join Free | My spintoband.com
China Ningbo Sanmin Import And Export Co.,Ltd. logo
Ningbo Sanmin Import And Export Co.,Ltd.
Ningbo Sanmin Import And Export Co.,Ltd.
Verified Supplier

8 Years

Home > Pneumatic Pulse Valve >

SANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO Type

Ningbo Sanmin Import And Export Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

SANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO Type

  • 1
  • 2

Brand Name : NBSANMINSE

Model Number : QA - ZT - 40S / 62S

Certification : ISO9001

Place of Origin : NINGBO

MOQ : 20

Price : Negotiation

Payment Terms : L/C, T/T, Western Union

Supply Ability : 11000 PCS / Year

Delivery Time : Negotiation

Packaging Details : Plastic Bags , Boxes , Carton , Pallet Or As Customer Advice

Pressure : 0 . 3 ~ 0 . 6 MPa

Temperature : - 25 ~ 60 ℃

Relative Humidity : ≤ 85 %

Medium : Clean Air

Voltage : DC24V / AC110V / Etc

Diaphragm : Double Diaphragm

Diameter : G1 - 1 / 2 " / G2 - 1 / 2 "

Body : ADC12 Die Cast

Contact Now

SANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO Type


Pulse valve is composed of pilot head, diaphragm and valve aluminum body. The back cavity area of diaphragm is bigger than the front one. The diaphragm is kept at the closed position due to the effect of big pressure.


Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.


The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.
The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning.


Material Construction

Body ADC12 die cast
Armature 430FR stainless steel
Diaphragm Nitrile or viton
Spring 321 Stainless steel
Fasteners 302 Stainless steel


Good Quality membranes shall be selected and used fo all the valves , with each part checked in each manufacturing procedure , and put into the assembly ling conforming to all the procedures . Every finished valve shall be taken the electriferous blowing test .


Common failure and troubleshooting

During installation and commissioning

Failure phenomena

1 . The valves cannot all be opened, but the leading part does act.

2 . Some valves do not work, but the others are normal.

3 . The valves cannot all be closed. There is leakage. There is no way to establish a gas dome.

4 . Some valves cannot be closed. There is leakage.

5 . A valve closing is slowly.

Possible Reason

1 . Check the gas dome pressure to see if it is too low.

2 . Check the valve coil connection and coil

3 ( 1 ) . Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves.

3 ( 2 ) . Z-valve. The valve inlet and blowing muzzle are installed backwards.

4 . There is some dirt or debris on the membrane, ii is blocking the moving iron core.

5 . The membrane orifice is blocked.

Troubleshooting

1 . Check the leakage

2 . Replace the accessories

3 ( 1 ) . Check the leakage

3 ( 2 ) . Re-install

4 . Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.

5 . Dredge the membrane orifice

During use period

Failure phenomena

1 . Some valves are leaking. The membrane cannot close tightly and the valve is always open a

little.

2 . Coil is hot and burned out.

3 . Voltage exists but the valve does not operate.

4 . Ambient temperature is below -20℃. The valve is leaking and cannot open.

Possible Reason

1 . There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked.

2 . It has been turned on for too long.

3 . Membrane is damaged and the orifice is blocked.

4 . Ambient temperature is too low and here is frost in the valve.

Troubleshooting

1 . Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.

2 . Check the working condition of the control system.

3 . Replace the accessories in time.

4 . Pay attention to insulation and maintaining proper temperatures.

SANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO TypeSANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO TypeSANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO TypeSANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO Type


Product Tags:

electromagnetic pulse valve

      

pulse jet solenoid valve

      
Wholesale SANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO Type from china suppliers

SANMIN Pneumatic Pulse Valve Dustproof Valve Clean Air 1 - 1 / 4 " ASCO Type Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Sanmin Import And Export Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0