Air Dust Proof Valve 3/4 " 1 " Pulse Jet Valve Pneumatic Two way Indsutry cement factory application

  • 1
  • 2

Brand Name : NBSANMINSE

Model Number : QD - Z - 20 / 25

Certification : ISO9001

Place of Origin : China

MOQ : 20

Price : Negotiation

Payment Terms : L/C, T/T, Western Union

Supply Ability : Negotiation

Delivery Time : Negotiation

Packaging Details : Plastic Bags , Boxes , Carton , Pallet Or As Customer Advice

Pressure : 0 . 3 ~ 0 . 6MPa

Temperature : - 25 ~ 60 ℃

Relative Humidity : ≤ 85 %

Medium : Clean Air

Voltage : DC24V , AC220V , ETC

Diaphragm : Nitrile or Viton

Diameter : G3 / 4 " , G1 "

Contact Now

QD - Z - 20 / 25 Series Electromagnetic Pulse Vave GOYEN Replace Right Angle Air Dust Proof Valve 3 / 4 " , 1 "


Usage

Electromagnetic valve ( Also called diaphragm valve ) is the” switch “for compressed air in the dust clean blowing system of the pulse bag filter . Controlled by the output signals of the pulse jet control device , it makes dust clean to the filter bags cell by cell to keep the resistance of thebaghouse within the set range and thus guarantee the processing functions and the dust collecting efficiency of the baghouse .

Z type electromagnetic pulse valves is a right angle valve , with the 90 degree , angle between the inlet and outlet , which is suitable for the installation connection between the gas dome and the baghouse blow tube provide good air flow and dust clean pulses satisfying the requirements .


Working Principle

The electrical signals from the pulse jet control device move the armature of the electromagnetic pulse valve . The air escape of the back gas cell opens and the back bag gas cell loses pressure quickly , thus the diaphragm moves back and the compressed air blows through the valve outlet . The electromagnetic pulse valve comes into the “open” condition .


Material Construction

Body ADC12 die cast
Armature 430FR stainless steel
Diaphragm Nitrile or viton
Spring 321 Stainless steel
Fasteners 302 Stainless steel

Good Quality membranes shall be selected and used fo all the valves , with each part checked in each manufacturing procedure , and put into the assembly ling conforming to all the procedures . Every finished valve shall be taken the electriferous blowing test .

Common failure and troubleshooting

Use period Failure phenomena Possible Reason Troubleshooting
During installation and commissioning The valves cannot all be opened, but the leading part does act. Check the gas dome pressure to see if it is too low. Check the leakage
Some valves do not work, but the others are normal. Check the valve coil connection and coil Replace the accessories
The valves cannot all be closed. There is leakage. There is no way to establish a gas dome. Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves. Check the leakage
Z-valve. The valve inlet and blowing muzzle are installed backwards. Re-install
Some valves cannot be closed. There is leakage. There is some dirt or debris on the membrane, ii is blocking the moving iron core. Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.
A valve closing is slowly. The membrane orifice is blocked. Dredge the membrane orifice
During use period

Some valves are leaking. The membrane cannot close tightly and the valve is always open a

little.

There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked. Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.
Coil is hot and burned out. It has been turned on for too long. Check the working condition of the control system.
Voltage exists but the valve does not operate. Membrane is damaged and the orifice is blocked. Replace the accessories in time.
Ambient temperature is below -20℃. The valve is leaking and cannot open. Ambient temperature is too low and here is frost in the valve. Pay attention to insulation and maintaining proper temperatures.


Air Dust Proof Valve 3/4 " 1 " Pulse Jet Valve Pneumatic Two way Indsutry cement factory application


Product Tags:

electromagnetic pulse valve

      

pulse air valve

      
Wholesale Air Dust Proof Valve 3/4 " 1 " Pulse Jet Valve Pneumatic Two way Indsutry cement factory application from china suppliers

Air Dust Proof Valve 3/4 " 1 " Pulse Jet Valve Pneumatic Two way Indsutry cement factory application Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Sanmin Import And Export Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0